3arr3j4a4 Relay Docs

  • document

    09 relay & hardstarts - SUPCO

    relay designed to be a Wire to Wire replacement for virtually any potential relay on the market. The SUPR is a replacement for potential, hard start, current and centrifugal start relays. It can be used on any single phase motor or air conditioning and refrigera-

  • document

    ATLAS COPCO Refrigeration Cycle Air Dryers

    38 2200700376 1 Relay 38 2200700347 1 Relay 3ARR3J4A4 39 2200709726 1 Capacitor 88/108/330-25/400 MFD 39 2200709728 1 Capacitor 100/330-30/440 MFD 40 2202250804 1 1 1 Kit insulation . Industrial Air division Parts List 8 2930 1462 00 FX 13, FX 14, FX 15 ...

  • document

    RS+3 Selection Report

    Start relay 3ARR3J4A4 $START_ACC PSC starting kit, 35 µF, 20 µF Page 7 of 8 file://C:\Documents and Settings\andrewl\Desktop\Danfoss Compressor Data\MTZ40-1.h... 12/29/2009. CSR starting kit, 35 µF, 20 µF, 100 µF CSR starting kit, prewired box, 35 µF, 20 µF, 100 µF

  • document

    Maneurop® reciprocating compressors - Frigocommerce

    3ARR3J4A4 NTZ068 20 10 100 60 Hz PSC/CSR* CSR only Models Run capacitors (1) Start capacitors (2) Start (A) μF (C) μF (B) μF relay NTZ048 15 10 100 3ARR3J4A4 NTZ068 25 25 135 NTZ096 30 15 135 NTZ108 30 15 135 NTZ136 30 15 135 ELECTRICAL CONNECTIONS AND WIRING Nominal capacitor values and relays

  • document

    240 VAC - Single Phase Circuit Breaker #4 (Proposed) FU-3

    Relay Coil Circuit Breaker #3 Circuit Breaker #2 Circuit Breaker #1 Crank Case Heater "A" Crank CaseHeater "B" Circuit Breaker #4 (Proposed) FU-3 ... 3ARR3J4A4 Start Relays for taking the start capacitor off line as the compressor comes up to about 3/4 speed Fig. 9 10 12

  • document

    Collection of datasheets Maneurop Reciprocating Compressors

    Start capacitor B + start relay 100 uF + 3ARR3J4A4 Maximum continuous current (MCC) 15 A Locked rotor amps (LRA) 41 A Motor protection Internal overload Recommended installation torques Mounting bolts 15 Nm Suction rotolock nut or valve 90 Nm

  • document

    www.antartic.cl

    Relay 3ARR3J4A4 3ARR3J4A4 15kQ-1W 230 v 220 Termostato . Manuel Antonio Tocornal 454, Santiago - Chi e antartice refrigeracion A-13 Maneuro RECIPROCATING COMPRESSORS -rel: 2635 1706 - Fax: 2635 1072 ventas@antartic cl w.vw_antartic cl

  • document

    Diagrama de Alambrado

    3ARR3J4A4 MARS 19003 44 1 , Monofásico (Para sistemas de voltaje nóminal de 208 volts use únicamente alambrado del tipo CSR) PSC (Sistema con capacitor permanente): ... arranque y relay): Este sistema puede usarse para circuitos de refrigeración con