3arr3j4a4 Relay Docs

  • document

    09 relay & hardstarts - SUPCO

    the relay. Supco Coil Terminal Terminals Cross Reference No. Voltage 1-2-3 4-5-6 Essex/RBM Honeywell 90340 24 power power 90-340 R8222D1014 90341 110/120 power power 90-341 R4222D1013 90342 208/240 power power 90-342 R4222N1021 ...

  • document

    MARS PRODUCT CROSS REFERENCE INFORMATION

    MARS PRODUCT CROSS REFERENCE INFORMATION 1. N/A 2. N/A 3. Use with (2) 92301 auxiliary contact kits. 4. Use with 92301 auxiliary contact kit. 5. N/A 6. ... Overload built into replacement relay. 18. N/A 19. N/A 20. N/A 21. Can use MARS #90999. 22. Check coil, use with 92301 auxiliary contact kit.

  • document

    60-65-C-2005

    C–64 COMPONENT universal replacement The MARS potential relay service kit has become an industry standard since its introduction twenty years ago.

  • document

    Relay Selection Guide - GE Digital Energy

    Distance relay applications are very different from overcurrent applications; selectivity is achieved by means of sensitivity (distance setting) and time delay, but the timing functions are almost always definite time rather than inverse time.

  • document

    INSTRUCTION SHEET: RBM Wiring Diagram and Cross Reference.

    INSTRUCTION SHEET: The Universal Potential Motor Starting Relay Wiring Diagram and Cross Reference. RBM 90-63 Potential Relay Continuous Coil Voltage 170 Pick Up Minimum 140 Maximum 153 Drop Out Maximum 65 90-64 Potential Relay Continuous Coil Voltage 395

  • document

    RS+3 Selection Report

    Start relay 3ARR3J4A4 $START_ACC PSC starting kit, 35 µF, 20 µF Page 7 of 8 file://C:\Documents and Settings\andrewl\Desktop\Danfoss Compressor Data\MTZ40-1.h... 12/29/2009. CSR starting kit, 35 µF, 20 µF, 100 µF CSR starting kit, prewired box, 35 µF, 20 µF, 100 µF

  • document

    RS+3 Selection Report

    RS+3 Selection Report Dec 29, 2009 1:04:25 PM General data Operating Conditions Performance data Cooling capacity in Btu/hr Type MTZ064-1 Code no. MTZ64-1VI

  • document

    240 VAC - Single Phase Circuit Breaker #4 (Proposed) FU-3

    Relay Coil Circuit Breaker #3 Circuit Breaker #2 Circuit Breaker #1 Crank Case Heater "A" Crank CaseHeater "B" Circuit Breaker #4 (Proposed) FU-3 ... 3ARR3J4A4 Start Relays for taking the start capacitor off line as the compressor comes up to about 3/4 speed Fig. 9 10 12

  • document

    Maneurop® reciprocating compressors - Frigocommerce

    MANEUROP® RECIPROCATING COMPRESSORS Features The Maneurop® NTZ series from Danfoss Commercial Compressors ... μF relay NTZ048 15 10 100 3ARR3J4A4 NTZ068 25 25 135 NTZ096 30 15 135 NTZ108 30 15 135 NTZ136 30 15 135 ELECTRICAL CONNECTIONS AND WIRING Nominal capacitor values

  • document

    Diagrama de Alambrado - Inicio

    3ARR3J4A4 MARS 19003 44 1 , Monofásico (Para sistemas de voltaje nóminal de 208 volts use únicamente alambrado del tipo CSR) PSC (Sistema con capacitor permanente): ... arranque y relay): Este sistema puede usarse para circuitos de refrigeración con

  • document

    www.antartic.cl

    Relay 3ARR3J4A4 3ARR3J4A4 15kQ-1W 230 v 220 Termostato . Manuel Antonio Tocornal 454, Santiago - Chi e antartice refrigeracion A-13 Maneuro RECIPROCATING COMPRESSORS -rel: 2635 1706 - Fax: 2635 1072 ventas@antartic cl